One step forward, one step back...
and round and round, that's not so hard. When data has to be passed back and forth, then a digital cable with a check-back channel should be used. The surge impedance for this cable is also set at 110 Ohm. Two of the 4 wires are responsible for the check-back function. The robust outer jacket is suitable for outdoor and permanent installation. Color coding according to DIN 47100. Due to the double shielding (AL/PT-foil + copper braiding) and wire coding it conforms with the generally applicable guidelines (VDE 0812/VDE 0207). The PE-version is halogen-free and resistant to saltwater, which makes it suitable for in-ground installation. The flexible longitudinal water-tight PUR-blend-version is suitable for outdoor application.
Advantages:
- Digital transmission over long distances due to the DMX and AES/EBU standards
- Excellent protection against electric interference (Cu mesh screen + AL/PT foil)
- Extremely robust due to the special tough jacket
Application:
- Networking of scanners and lighting systems with check-back function
- Connection of digital control units and devices of all kinds
| Name |
Binary 434 DMX512 |
| Properties |
OFC oxygen free copper |
| Properties |
Analog |
| Properties |
Digital 110 Ω AES / EBU |
| Application area |
Installation |
| Application area |
Studio / Broadcast |
| Application area |
Mobile outdoor / indoor |
| Application area |
ELA 100 V |
| Application area |
Stage / live |
| Application |
DMX |
| Colour |
black |
| Colour detailed |
black |
| Signal transmission |
symmetrical |
| Construction |
[2(2LI2YS0,34mm²)(ST)]CY |
| Jacket material |
PVC |
| Jacket Ø [mm] |
7,00 |
| Number of Channels (AES/EBU, DMX) |
1 |
| Inner conductor (AES/EBU, DMX) |
4 |
| Inner conductor (AES/EBU, DMX) [mm²] |
0,34 |
| Inner conductor Ø (AES/EBU, DMX) [mm] |
0,66 |
| AWG (AES/EBU, DMX) |
22 |
| Shielding |
Copper-cross mesh, tined + AL / PT foil |
| Copper strands (AES/EBU, DMX) |
7 |
| Copper strand Ø (AES/EBU, DMX) [mm] |
0,25 |
| Conductor insulation material |
PE |
| Conductor insulation Ø [mm] |
1,70 |
| Weight per 1 m [g] |
65 |
| UV-resistant |
yes |
| Fire load per m [kWh] |
0,22 |
| Style variant |
round |
| Shielding factor [%] |
100 |
| Packing |
100 m spool |
| Temperature min. [°C] |
-25 |
| Temperature max. [°C] |
70 |
| Width [mm] |
7 |
| Height [mm] |
7 |
| Capac. cond./cond. per 1 m (AES/EBU, DMX) [pF] |
58 |
| Capacity wire/wire at 1 ft. (AES/EBU, DMX) [pF] |
17,6784 |
| Capac. cond./shield. per 1 m (AES/EBU, DMX) [pF] |
100 |
| Capacity wire/electic screen at 1 ft. (AES/EBU, DMX) [pF] |
30,48 |
| Impedance [Ω] |
110 |
| Insulation resist. per 1 km [GΩ] |
5 |
| Insulation resist. per 1000 feet [GΩ] |
1,524 |
| Insulation resist. per 1 km (AES/EBU, DMX) [GΩ] |
5 |
| Insulation resist. per 1000 feet (AES/EBU, DMX) [GΩ] |
1,524 |
| Conductor resistance per 1 km [Ω] |
53 |
| Conductor resistance per 1000 ft. [Ω] |
16,1544 |
| Shield. resistance per 1 km [Ω] |
15 |
| Shield. resistance per 1000 ft. [Ω] |
4,572 |
| EAN |
4049371002387 |
|
Fca |